Point of viewAssets & integrity

Pipeline integrity data should be right where it is captured, not fixed in the office

Cathodic-protection surveys are walked along remote rights of way with no signal. When readings are typed in, positions approximate and anomalies found weeks later, integrity decisions start from cleaned-up data. Capturing it right at source changes that.

5 min read By · Point of view
4
cathodic-protection survey types captured offline by the field collector we built: CIS, DCVG, ACVG and ACCA1

Key takeaways

  • Integrity decisions are only as good as the survey data behind them.
  • An offline-first app lets every reading land on the device before the network is ever needed.
  • Instrument readings over Bluetooth, GPS with its accuracy and photos remove transcription and guesswork.
  • Flagging under-protected sections at the point of capture sends the surveyor back before they leave the site.

Pipeline operators in oil, gas and city gas distribution walk thousands of kilometres of right of way to check that cathodic protection is doing its job. Much of that ground has no signal, and much of the data is still cleaned up after the fact by subject-matter experts in the office.

What goes wrong when data is cleaned later

  • Readings transcribed by hand from the voltmeter
  • Positions approximate, with no record of GPS accuracy
  • Under-protected sections found weeks after the survey
  • Uploads lost or duplicated on poor networks

What we built

For a pipeline-integrity services firm, we built an offline-first mobile collector for cathodic-protection surveys. Every reading lands in on-device storage first; a digital voltmeter connects over Bluetooth; each reading carries its GPS position and accuracy; and readings that breach the protection criterion are flagged on the spot. Sync runs in batches with acknowledgement and retry, and a CSV export matches the platform's import mapping.

Exhibit 1

Four survey types, one capture surface

As built

SurveyWhat it finds
CISProtection levels along the line, on and off potentials
DCVGCoating defects and their severity
ACVGCoating defects from an applied AC signal
ACCACoating condition from signal current loss

Note: Survey types supported by the collector.

Source: DaasLabs, “Delivered for energy, pipelines and heavy industry: energy case study” (2026)

Where to start

Start with one line and one survey type, run the collector alongside the current process for a season, and compare the time from survey to integrity decision.

For executives

What this means for your bank

  1. Fix data quality at capture, not in the office.
  2. Design for no signal: offline first, sync later.
  3. Carry GPS accuracy and photos with every reading.
  4. Keep every dig and repair decision with an engineer.
Put it to work

How DaasLabs can help

Modernise integrity data in our Oil, Gas & Asset Integrity service.

Learn more

Meet the oil, gas and pipelines agent squad.

Learn more

Read the full case study.

Learn more

Sources

  1. 1

Figures are drawn from the cited public sources. Opinions labelled “DaasLabs point of view” are our own.

Stay informed

Get new energy and utilities insights in your inbox

New perspectives on AI, data and transformation in energy and utilities — a few times a month. Browse all insights.